Walls and hardware
Reference

Walls and hardware

One row per wall and hardware combination, with the rating the maker publishes, the conditions that rating assumes, and where the figure comes from. Filter it to the wall you have.

Every figure in the ultimate column is the maker's own published test value, taken from its technical sheets rather than its product pages. The working column is that figure divided by four, because every one of these makers states that industry practice is a quarter of the ultimate test load. Nothing in this table is added to anything else in it.

Wall and hardwareUltimate, as publishedWorking, at a quarterConditions the figure assumes
Metal toggle bolt, 3/16 inch, in 1/2 inch drywall238 lb tensileabout 60 lb1/2 inch drill; failure recorded as breakage of the drywall portion; minimum clearance behind the wall 1-7/8 inches; load held close to the wall
Metal toggle bolt, 3/16 inch, in 5/8 inch drywall356 lb tensileabout 89 lbAs above, with thicker board
Metal toggle bolt, 3/16 inch, 1/2 inch drywall with a 25 gauge steel stud behind412 lb tensileabout 103 lbA different test condition, not a bonus for the same installation
Metal toggle bolt, 3/16 inch, in concrete block802 lb tensileabout 200 lbConcrete block; the same maker's product page quotes this figure with no safety factor mentioned
Metal toggle bolt, 1/4 inch, in 1/2 inch drywall265 lb tensileabout 66 lb1/2 inch drill
Self-drilling drywall anchor, regular, in 9.5 mm drywall25 kg (about 55 lb) tensileabout 6 kg (14 lb)Tested with a 4.0 by 40 mm screw; picture frames and mirrors are named applications
Self-drilling drywall anchor, regular, in 12.5 mm drywall36 kg (about 79 lb) tensileabout 9 kg (20 lb)Same screw; clearance behind the wall 29 mm
Self-drilling drywall anchor, regular, in 15 mm drywall61 kg (about 134 lb) tensileabout 15 kg (34 lb)Same screw; maximum drywall thickness 16 mm
Self-drilling drywall anchor, mini, in 12.5 mm drywall29 kg (about 64 lb) tensileabout 7 kg (16 lb)Tested with a 3.5 by 30 mm screw; clearance 16 mm
Plastic toggle anchor (TB), in 12.5 mm drywall65 kg (about 143 lb) tensileabout 16 kg (36 lb)8 mm hole, 4.0 mm screw; needs 19 mm of clearance behind the wall to open
Plastic toggle anchor (TB), in 9.5 mm drywall44 kg (about 97 lb) tensileabout 11 kg (24 lb)As above
Plastic toggle anchor (TC), in 15 mm drywall72 kg (about 159 lb) tensileabout 18 kg (40 lb)Grip range 15 to 19 mm
Solid-wall anchor, 1/4 inch size, in 1/2 inch drywall69 lb tensileabout 17 lbPublished in a 2007 catalogue revision; intended base materials include masonry, tile, plaster and drywall
Solid-wall anchor, 1/4 inch size, in 4000 psi concrete2,633 lb tensileabout 658 lbThe anchor is not the limit at that point; the fixing and the thing hanging are
Masonry screw, 3/16 inch at 1 inch embedment, 4000 psi concrete650 lb tensileabout 163 lb5/32 inch bit; full capacity needs 1-7/8 inch edge distance and 3 inch spacing, with published reduction factors below that
Masonry screw, 3/16 inch at 1-3/4 inch embedment, 4000 psi concrete1,460 lb tensileabout 365 lbDeeper embedment, same bit
Masonry screw, 1/4 inch at 1 inch embedment, 4000 psi concrete800 lb tensileabout 200 lb3/16 inch bit; full-capacity edge distance 2-1/2 inches, spacing 4 inches
Masonry screw, 3/16 inch at 1 inch, medium weight hollow block340 lb tensileabout 85 lbLightweight block is published at 220 lb
Lag bolt into a stud (museum screen practice)No consumer rating publishedNot applicableA federal museum leaflet's practice for a storage screen: 1/4 inch lag bolts with washers through 1/4 inch clearance holes about 18 inches apart, into 1/8 inch pilot holes in studs commonly spaced 16 to 24 inches on center
Plaster and lathNo published rating found for any consumer anchor in plaster and lath specificallyNot applicableThree-coat plaster is a scratch and brown coat at about 3/8 inch each with a 1/8 inch finish coat, over wood, metal or gypsum lath. Drywall ratings do not transfer. Find a stud
D-rings, screw eyes, strap hangersNo tested rating found. Figures exist only on retail listings, disagree with each other for apparently the same part, and state no test basisNot calculableOne maker's answer on a retail listing says the ratings assume the hanger is nailed into a stud, are for comparative purposes only, and are not cumulative
Strap hanger (one maker's published figure)150 lb per hanger; 200 lb per hanger with a molly boltNot stated by the makerNo test conditions published; the same maker states 300 lb with two hangers, which is the claim this manual does not act on
Picture wireNo rated standard found. Circulating gauge tables are supplier charts that disagreeNot calculableOne trade supplier states only that the wire's tensile strength should be at least double the picture's weight. A wire sold as a "10 kg" wire is named by maximum picture weight, not breaking strength
Museum-practice hangers (one practitioner guide)Adjustable J-hook 50 lb per hook; one proprietary hanger 10 to 75 lb; another 22 to 100 lbNot statedFrom a practitioner guide prepared with a museum packing and handling network, which also gives the margin rule: hardware should support 25 to 50 percent more than the artwork's maximum weight
Rail system, one maker's tracks20 lb/ft (30 kg/m) for most rails; 50 lb/ft (74 kg/m) for its heaviest wall trackNot statedNo wall-fastener condition published with the table
Rail system, another maker's rail45 kg per metreNot statedWall mounted, with three rail clips and three screws per linear metre
Rail system cords and hooksPerlon cord with a light hook 4 kg; perlon with the heavier hook 15 kg; coated steel cable 10 kg; steel cable 20 kg. Another maker: stainless cable 45 lb, nylon cord 15 lb, hooks from 12 to 110 lbNot statedPublished per hook-and-cord combination. The cord and hook, not the rail, are usually what limits a rail system
Picture rail hook on a traditional rail20 kg maximum per hook and cableNot statedThe maker's own footnotes: the rails must be fastened securely into wall studs, and its statement that weights can be doubled with two hangers assumes the load is evenly distributed on both hooks at all times
Adhesive hooks and stripsNo maker figure could be reached. Every path to the maker's own weight-limit page returned an error during this researchNot calculable from any source we can citeRead the limit printed on the package you buy, and follow the maker's own surface list. A museum educator's slides describe adhesive hooks as a good option when you cannot put holes in the wall and otherwise not to use them
Picture nail into a studNo consumer rating publishedNot applicableThe no-drill option with real holding. Most leases permit it, and it puts the load into framing rather than into board

How to read this table

  • Ultimate is not working. The maker publishes the load the anchor sustained in a laboratory test and then tells you to use a quarter of it. The quarter is the number to design to.
  • Conditions travel with the number. Board thickness, hole size, screw size, cavity depth and the load being held close to the wall are all part of the rating. Copy them into the hardware sheet along with the figure.
  • The table never adds two fixings together. The makers disagree about whether that is allowed, and no engineering or standards source in this research settles it. If one fixing does not cover the weight, use a bigger one or a stud.
  • The frame side has no test data. That is the honest finding, and it is why this manual treats D-rings and wire as a matter of practice rather than of rating.
  • A rating is about a product, not about your wall. The maker says the base material's age, capacity and condition must be considered, and it cannot know any of them.
Before you drill

Find out what is behind the wall. Cable and pipe run inside walls and a stud finder is a guide, not proof. This manual prints no code setback figure, because the only free sources for one were trade forums that disagreed on how it is measured. Walls and trim in a home built before 1978 may hold lead paint, and older plaster or textured surfaces may hold asbestos; a federal agency names drilling among the activities that release asbestos fibers and says to leave undamaged material alone.

Limits

These are makers' published figures for their own products, read on 2026-11-03, with the working column calculated at the quarter the makers themselves state. They are not ratings for your wall, they are not advice about a particular installation, and they are not a substitute for the instructions in the packet. Where a cell says no figure was found, that is the finding, and the honest response is to choose a product whose maker has tested it in your wall.